Technical Information Pull Over TestFixingLoad Steel Thickness (Grade Z35)0.5mm0.7mm1.0mmLight Section 5.5mm Dia Inc 16mm WasherKN2.965.267.25Light Section 5.5mm Dia Inc 19mm WasherKN3.085.87.64 Shear Test GaugeLoad KNLight Section 4.8mm Dia10g6.96Light Section 5.5mm Dia12g7.32Timberfix 6.3mm Dia14g9.68 Pull Out TestPull Out Test Steel Thickness (Grade Z35)FixingLoad1.251.522.533.5Light Section 5.5 mm DiameterKN1.962.562.74.026.87.1 Pull Out Test Steel Thickness Grade (Grade Z35)FixingLoad3.5mm5681012Heavy Section 5.5mm DiameterKN8.1510.0611.21Threads Will Strip Above 6mm Thick Pull Out TestSampleGaugeTimber ThickConstruction GradeTimberfix 6.3mm x 25mm14g1.89Timberfix 6.3mm x 32mm14g2.09Timberfix 6.3mm x 4514g2.86 Torsional TestFixingGaugeLoadLight Section 4.8mm Diameter10g6.9NmLight Section 5.5mm Diameter12g10.5NmTimberfix 6.3mm Diameter14g16.9Nm Tensile TestFixingGaugeLoad KNLight Section 4.8mm Diameter10g10.02Light Section 5.5mm Diameter12g16.2Timberfix 6.3mm Diameter14g20.62