Pull  Over Test

Fixing

Load

 

 

Steel Thickness (Grade Z35)

0.5mm

0.7mm

1.0mm

Light Section 5.5mm Dia Inc 16mm Washer

KN

2.96

5.26

7.25

Light Section 5.5mm Dia Inc 19mm Washer

KN

3.08

5.8

7.64

 

Shear Test

 

Gauge

Load KN

Light Section 4.8mm Dia

10g

6.96

Light Section 5.5mm Dia

12g

7.32

Timberfix 6.3mm Dia

14g

9.68

 

Pull Out Test

Pull Out Test

 

Steel Thickness (Grade Z35)

Fixing

Load

1.25

1.5

2

2.5

3

3.5

Light Section 5.5 mm Diameter

KN

1.96

2.56

2.7

4.02

6.8

7.1

 

Pull Out Test

 

 

Steel Thickness Grade (Grade Z35)

Fixing

Load

3.5mm

5

6

8

10

12

Heavy Section 5.5mm Diameter

KN

8.15

10.06

11.21

Threads Will Strip Above 6mm Thick

 

Pull Out Test

Sample

Gauge

Timber Thick

Construction Grade

Timberfix 6.3mm x 25mm

14g

1.89

Timberfix 6.3mm x 32mm

14g

2.09

Timberfix 6.3mm x 45

14g

2.86

 

Torsional Test

Fixing

Gauge

Load

Light Section 4.8mm Diameter

10g

6.9Nm

Light Section 5.5mm Diameter

12g

10.5Nm

Timberfix 6.3mm Diameter

14g

16.9Nm

 

Tensile Test

Fixing

Gauge

Load KN

Light Section 4.8mm Diameter

10g

10.02

Light Section 5.5mm Diameter

12g

16.2

Timberfix 6.3mm Diameter

14g

20.62